Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38603625

RESUMO

We present a case of a 52-year old woman with cardiogenic shock (CS) with refractory right ventricular (RV) failure due to spontaneous dissection of the right coronary artery (RCA). She remained dependent on mechanical support for several weeks and both RV assist device (RVAD) implantation and bidirectional cavopulmonary anastomosis (BCPA) were explored as long-term support options. History of malignancy and possible RV functional recovery resulted in a decision in favour of BCPA and concomitant tricuspid valve (TV) annuloplasty. Postoperatively her clinical condition improved significantly and she could be discharged home. Echocardiography showed normalization of RV dimensions and slight improvement of RV function.

2.
J Cardiovasc Dev Dis ; 11(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38392265

RESUMO

BACKGROUND: Survival and quality-of-life of left ventricular assist device (LVAD) recipients improved significantly because of growing experience and technological advances. However, LVAD-related complication rates, including recurrent episodes of congestion, remain high. Early detection of fluid retention to provide a time-window for medical intervention is the pillar in preventing hospitalizations. The multisensory HeartLogicTM algorithm accurately detected impending congestion in ambulant heart failure patients. The aim of the current study is to investigate the feasibility of HeartLogicTM-driven care in LVAD patients. METHODS: Consecutive LVAD destination therapy patients were followed-up according the structured HeartLogicTM-based heart failure carepath. An alert triggered a device check-up, and the heart failure team contacted the patient to evaluate for signs and symptoms of impending congestion. An alert was adjudicated as true positive or unexplained. An episode of congestion not preceded by an alert was deemed as a false negative. RESULTS: Data from 7 patients were included: the median age was 67 years [IQR 61-71], 71% were male and 71% had a non-ischemic aetiology. Total follow-up entailed 12 patient-years. All patients experienced at least one alert. In total, 33 alerts were observed. Majority of alerts (70%, n = 23) were driven by congestion and one alerts (15%) were clinically meaningful but not primarily fluid-retention-related (e.g., altered hemodynamic triggered by a pump thrombosis). Of all the alerts, five (15%) were classified as an unexplained alert, and during follow-up, four false negative episodes were documented. CONCLUSIONS: HeartLogicTM-driven care with continuous monitoring to detect impending fluid retention in LVAD patients was feasible and deserves further prospective validation.

3.
Ann Thorac Surg ; 117(1): 120-126, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37714504

RESUMO

BACKGROUND: Real-world evidence supporting the reproducibility and superiority of valve repair over replacement in active mitral valve infective endocarditis is lacking. METHODS: Data from a prospective nationwide database, including all cardiac surgical procedures in The Netherlands, were used. Adult patients undergoing primary mitral valve intervention who had a diagnosis of active infective endocarditis and who underwent surgery between 2013 and 2020 were included. Survival analysis was performed for the whole follow-up period as well as after applying the landmark of 90 days. RESULTS: Of 715 patients who met the inclusion criteria, 294 (41.1%) underwent valve repair. Mitral valve repair rates decreased slightly over the course of the study. The early mortality rate was 13.0%, and a trend of steadily declining early mortality rates over the course of the study, despite a steady increase in patient complexity, was observed. On risk-adjusted analysis, mitral valve replacement demonstrated inferior results when compared with valve repair (adjusted hazard ratio, 2.216; 95% CI, 1.425-3.448; P < .001), even after a landmark analysis was performed (adjusted hazard ratio 2.489; 95% CI, 1.124-5.516; P = .025). These results were confirmed by a propensity score-adjusted analysis (adjusted hazard ratio 2.251; 95% CI, 1.029-4.21; P = .042). CONCLUSIONS: Contemporary trends in mitral valve surgery for active infective endocarditis suggest growing patient complexity but slightly declining early mortality rates. A trend of decreasing mitral valve repair rates was seen. The results of this study suggest improved late outcomes of valve repair compared with valve replacement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Valva Mitral/cirurgia , Estudos Prospectivos , Reprodutibilidade dos Testes , Endocardite/diagnóstico , Endocardite Bacteriana/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Resultado do Tratamento
4.
Am J Cardiol ; 210: 58-64, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37838070

RESUMO

Oral anticoagulation with vitamin K antagonists is currently advised for a period of 3 months after surgical mitral valve repair, regardless of the rhythm status. The evidence supporting this recommendation is weak and recent studies have challenged the safety and efficacy of this recommendation. A systematic review of literature was conducted by searching PubMed, Embase, Web of Science, Emcare, and Cochrane Library databases for original publications comparing the efficacy and safety of oral anticoagulation with vitamin K antagonists to antiplatelet treatment early after mitral valve surgery in patients with no atrial fibrillation. Study end points included thromboembolic complications, bleeding complications and survival. A total of 5 studies, including 5,093 patients, met the inclusion criteria; 2,824 patients were included in the oral anticoagulation and 2,269 in the antiplatelet treatment group. Pooled analyses demonstrated no beneficial effect of oral anticoagulation on the incidence of thromboembolic complications (risk ratio 1.14, 95% confidence interval 0.76 to 1.70, p = 0.53, I2 = 8%). Moreover, oral anticoagulation did not result in a significantly increased risk of bleeding complications (risk ratio 0.89, 95% confidence interval 0.32 to 2.44, p = 0.81, I2 = 87%). When combining the efficacy and safety end points, no difference was observed between groups (risk ratio 1.01, 95% confidence interval 0.51 to 1.97, p = 0.99 I2 = 85%). Likewise, mortality did not differ between groups (risk ratio 0.89, 95% confidence interval 0.15 to 5.23, p = 0.90 I2 = 71%). Our results confirmed the safety but failed to confirm the efficacy of oral anticoagulation in patients who underwent mitral valve surgery. A randomized controlled trial would provide the evidence needed to support treatment recommendations.


Assuntos
Valva Mitral , Tromboembolia , Humanos , Valva Mitral/cirurgia , Anticoagulantes , Hemorragia/induzido quimicamente , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Vitamina K , Administração Oral
5.
J Cardiol ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38103635

RESUMO

BACKGROUND: Clinical and echocardiographic results of valve repair for mitral regurgitation in the setting of atrial fibrillation are poorly studied. METHODS: Between January 2008 and December 2020, 89 patients underwent valve repair for mitral regurgitation in the setting of atrial fibrillation. Clinical and echocardiographic follow-up data were collected and studied. The primary composite endpoint consisted of all-cause mortality or hospitalization for heart failure. RESULTS: Valve repair with true-sized annuloplasty was performed in 83 (93 %) and restrictive annuloplasty in 6 (7 %) patients. Early mortality occurred in 3 (3 %) and residual mitral regurgitation in 1 (1 %) patient. During a median follow-up of 5.4 years (interquartile range 3.4-9.5), 25 patients died, 6 due to end-stage heart failure. Ten patients were hospitalized for heart failure. The estimated event-free survival rate at 10 years was 48.2 % (95 % CI 33.5 %-62.9 %). Recurrent mitral regurgitation was observed in 14 patients and most often caused by leaflet tethering. When analyzed as a time-dependent variable, recurrent regurgitation was related to the occurrence of the primary endpoint (hazard ratio 3.192, 95 % CI 1.219-8.359, p = 0.018). On exploratory sub-analyses, no recurrent regurgitation was observed after restrictive annuloplasty or in patients with paroxysmal atrial fibrillation. Moreover, recurrent regurgitation was observed more often when signs of left ventricular impairment were present preoperatively. CONCLUSIONS: Despite good initial results, recurrent regurgitation was a frequent observation after valve repair for mitral regurgitation in atrial fibrillation and had an effect on heart failure related morbidity and mortality. Refinements in the timing of surgery and surgical technique might help improve outcomes.

6.
Eur Heart J Case Rep ; 7(10): ytad418, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37811153

RESUMO

Background: Cardiac paragangliomas are extremely rare neuroendocrine tumours derived from neural crest cells that represent <2% of all paragangliomas. Approximately 35-40% of all paragangliomas are associated with inherited syndromes such as mutation in the succinate dehydrogenase (SDH) enzyme. Case summary: A 44-year-old male with an SDH complex subunit D (SDHD) mutation was diagnosed with an intracardiac paraganglioma attached to the left main coronary artery. Multimodality imaging, including gallium dotatate positron emission tomography computed tomography, cardiac magnetic resonance imaging, and coronary computed tomography angiography (CCTA) confirmed the suspected intracardiac paraganglioma. During follow-up with a CCTA, the mass showed growth, and surgical removal was recommended to anticipate on the risk of compression of the left main coronary artery. Prior to surgery, coronary angiography was performed, which showed no coronary calcifications. The highly vascularized paraganglioma was visible near the left main and proximal left anterior descending artery. The intracardiac paraganglioma was successfully removed through a median sternotomy with cardiopulmonary bypass, without any complications. The post-operative course was uneventful, and histological examination confirmed the diagnosis of a paraganglioma. Discussion: Intracardiac paragangliomas in the vicinity of the left main coronary artery are rare, and surgical removal may be challenging. Therefore, screening and the use of multiple imaging modalities in patients with SDHD mutations prior to surgery is of major importance.

7.
Eur J Cardiothorac Surg ; 64(3)2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37688566

RESUMO

OBJECTIVES: The clinical importance of optimal post-repair mitral valve diastolic performance is increasingly being recognized. The haemodynamic effect of a partial annuloplasty band implantation, in comparison to a full ring, remains insufficiently explored. METHODS: Patients undergoing mitral valve repair for pure degenerative disease between 2011 and 2019 at 2 experienced heart valve centres were eligible for inclusion. Exclusion criteria were concomitant procedures other than tricuspid valve repair and ablation procedures for atrial fibrillation. Pre-discharge and follow-up echocardiograms (1-4 years after surgery) were analysed to assess haemodynamic mitral valve performance. RESULTS: Of 535 patients meeting the inclusion criteria, 364 (68.0%) patients underwent full annuloplasty ring and 171 (31.0%) partial band implantation. On predischarge echocardiogram, post-repair mitral valve gradient and area did not differ between groups [2.89 mmHg (IQR 2.26-3.72) vs 2.60 mmHg (IQR 1.91-3.55), P = 0.19 and 1.98 cm2 (IQR 1.66-2.46) vs 2.03 cm2 (IQR 1.55-3.06), P = 0.15]. However, multivariable linear regression analysis demonstrated band annuloplasty as a determinant of larger valve area (coefficient 0.467 cm2, standard error 0.105, P < 0.001). On multivariable analysis, no significant impact on post-repair gradient was observed (-0.370 mmHg, standard error 0.167, P = 0.36). At follow-up, the differences between groups disappeared and multivariable regression analysis failed to demonstrate a significant impact of annuloplasty device type on mitral valve gradient (coefficient -0.095 mmHg, standard error 0.171, P = 1.00) or area (coefficient -0.085 cm2, standard error 0.120, P = 1.00). These results were confirmed with a linear mixed model analysis. CONCLUSIONS: Partial band annuloplasty was related to an improved haemodynamic profile directly after valve repair for degenerative disease but the effect was short-lived. Our results suggest that the type of annuloplasty device has no durable impact on diastolic valve performance.


Assuntos
Fibrilação Atrial , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Tricúspide , Cateteres , Hemodinâmica
8.
Front Cardiovasc Med ; 10: 1156495, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37293277

RESUMO

Surgical mitral valve repair through median sternotomy has long presented the treatment of choice for degenerative mitral valve disease. In recent decades, minimal invasive surgical techniques have been developed and are now gaining widespread popularity. Robotic cardiac surgery presents an emerging field, initially adopted only by selected centres, mostly in the United States. In recent years, the number of centers interested in robotic mitral valve surgery has grown with an increasing adoption in Europe as well. Increasing interest and surgical experience gained are stimulating further developments in the field and the full potential of robotic mitral valve surgery remains to be developed.

9.
J Intern Med ; 294(3): 347-357, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37340835

RESUMO

BACKGROUND: Optogenetics could offer a solution to the current lack of an ambulatory method for the rapid automated cardioversion of atrial fibrillation (AF), but key translational aspects remain to be studied. OBJECTIVE: To investigate whether optogenetic cardioversion of AF is effective in the aged heart and whether sufficient light penetrates the human atrial wall. METHODS: Atria of adult and aged rats were optogenetically modified to express light-gated ion channels (i.e., red-activatable channelrhodopsin), followed by AF induction and atrial illumination to determine the effectivity of optogenetic cardioversion. The irradiance level was determined by light transmittance measurements on human atrial tissue. RESULTS: AF could be effectively terminated in the remodeled atria of aged rats (97%, n = 6). Subsequently, ex vivo experiments using human atrial auricles demonstrated that 565-nm light pulses at an intensity of 25 mW/mm2 achieved the complete penetration of the atrial wall. Applying such irradiation onto the chest of adult rats resulted in transthoracic atrial illumination as evidenced by the optogenetic cardioversion of AF (90%, n = 4). CONCLUSION: Transthoracic optogenetic cardioversion of AF is effective in the aged rat heart using irradiation levels compatible with human atrial transmural light penetration.


Assuntos
Fibrilação Atrial , Adulto , Humanos , Animais , Ratos , Fibrilação Atrial/terapia , Optogenética/métodos , Cardioversão Elétrica , Iluminação , Átrios do Coração/efeitos da radiação
10.
Int J Cardiol ; 387: 131099, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37263356

RESUMO

OBJECTIVE: Studies investigating the efficacy of concomitant surgical atrial fibrillation (AF) ablation in hypertrophic obstructive cardiomyopathy (HOCM) patients undergoing myectomy are scarce and limited in terms of sample size. We aim to summarize current outcomes of concomitant surgical AF ablation in HOCM patients undergoing surgical myectomy. METHODS: This systematic review and meta-analysis was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We included all studies reporting any of the following outcomes of concomitant surgical AF ablation in HOCM patients: freedom from recurrence of AF, overall survival and complications. Outcomes were evaluated using traditional meta-analysis at given time-points and using pooled Kaplan-Meier curves. RESULTS: A total of 13 studies were included, resulting in a total of 616 individual patients available for analysis. AF was paroxysmal in 68.1% of the patients (95% CI 56.0-78.2%; I2 = 87.1%; 8 studies, 583 participants). The majority of patients (86.2%) underwent either conventional Cox Maze III or IV (95% CI 39.7-98.3%; I2 = 92.4%; 8 studies, 616 patients) procedure. The incidence of early post-operative pacemaker implantation was 6.1% (95% CI 3.1-11.8%). Overall survival at 3, 5 and 7 years was 95.6% (95% CI 93.4-97.9%), 93.6% (95% CI 90.8-96.5%) and 90.5% (95% CI 86.5-94.6%), respectively. Freedom from recurrent AF at 3, 5 and 7 years was 77.6% (95% CI 73.7-81.7%), 70.6% (95% CI 65.8-75.7) and 63.2% (95% CI 56.2-73.8%), respectively. CONCLUSION: This meta-analysis supports concomitant surgical AF ablation at the time of surgical myectomy in HOCM patients, as it seems to be safe and effective in terminating AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Ablação por Cateter/métodos
11.
Front Cardiovasc Med ; 10: 1094969, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180783

RESUMO

Surgical mitral valve repair, performed either through median sternotomy or minimal invasive approach, presents the gold standard treatment for degenerative mitral valve disease. In dedicated centres, high repair and low complication rates have been established with excellent valve repair durability. Recently, new techniques have been introduced, that allow mitral valve repair to be performed through small surgical incisions and while avoiding cardio-pulmonary bypass. These new techniques, however, conceptually differ significantly when compared to surgical repair and it remains questionable whether they are capable of reproducing the results of surgical treatment.

12.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36951528

RESUMO

OBJECTIVES: Aortic root abscess can spread to include adjacent cardiac structures, including the central or intervalvular fibrous body and mitral valve. After radical debridement, complex surgical correction is needed. We describe the results of our mitral valve sparing approach. METHODS: Between January 2004 and December 2020, 60 patients underwent operation for infective endocarditis of the aortic root with extension towards the mitral valve at 2 centres in the Netherlands. Early and late clinical and echocardiographic outcomes were studied. RESULTS: Prosthetic valve endocarditis was present in 42 (70%) patients and emergent or salvage surgery was performed in 8 (13%) patients. After radical debridement of all infected tissue, mitral valve repair was feasible in 48 (80%) patients. Early mortality occurred in 11 (18%) patients while mechanical circulatory support was needed in 8 (13%) patients. At 10 years after surgery, the estimated reintervention-free survival rate was 51.9% (95% confidence interval 37.0-66.8%). Eight patients underwent reintervention; this was more common in patients who underwent aortic valve rather than root replacement and in patients in whom mitral valve repair was performed without ring annuloplasty. For 48 patients who underwent mitral valve repair, the estimated freedom from recurrent mitral regurgitation rate was 64.4% (95% confidence interval 40.1-88.7%) at 10 years after surgery. CONCLUSIONS: Surgical intervention for extensive infective endocarditis of the aortic root is related to reasonable perioperative morbidity and mortality. Optimal surgical technique is crucial to lower the risk of late reintervention. Mitral valve repair is feasible in the majority of patients with satisfactory durability.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Endocardite Bacteriana/cirurgia , Aorta Torácica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
14.
Ann Thorac Surg ; 116(6): 1161-1167, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36804598

RESUMO

BACKGROUND: An asymptomatic respiratory viral infection during cardiac surgery could lead to pulmonary complications and increased mortality. For elective surgery, testing for respiratory viral infection before surgery or vaccination could reduce the number of these pulmonary complications. The aim of this study was to investigate the association between influenzalike illness (ILI) seasons and prolonged mechanical ventilation and inhospital mortality in a Dutch cohort of adult elective cardiac surgery patients. METHODS: Cardiac surgery patients who were admitted to the intensive care unit between January 1, 2014, and February 1, 2020, were included. The primary endpoint was the duration of invasive mechanical ventilation in the ILI season compared with baseline season. Secondary endpoints were the median Pao2 to fraction of inspired oxygen ratio on days 1, 3, and 7 and postoperative inhospital mortality. RESULTS: A total of 42,277 patients underwent cardiac surgery, 12,994 (30.7%) in the ILI season, 15,843 (37.5%) in the intermediate season, and 13,440 (31.8%) in the baseline season. No hazard rates indicative of a longer duration of invasive mechanical ventilation during the ILI season were found. No differences were found for the median Pao2 to fraction of inspired oxygen ratio between seasons. However, inhospital mortality was higher in the ILI season compared with baseline season (odds ratio 1.67; 95% CI, 1.14-2.46). CONCLUSIONS: Patients undergoing cardiac surgery during the ILI season were at increased risk of inhospital mortality compared with patients in the baseline season. No evidence was found that this difference is caused by direct postoperative pulmonary complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Influenza Humana , Viroses , Adulto , Humanos , Influenza Humana/epidemiologia , Estações do Ano , Estudos de Coortes , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Oxigênio
15.
Neth Heart J ; 31(5): 189-195, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36723773

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) therapy is an established treatment for advanced heart failure with reduced ejection fraction. We evaluated the characteristics and clinical outcomes of patients implanted with an LVAD in the Netherlands. METHODS: Patients implanted with an LVAD in the Netherlands between 2016 and 2020 were included in the analysis. Baseline characteristics entered into this registry, as well as clinical outcomes (death on device, heart transplantation) and major adverse events (device dysfunction, major bleeding, major infection and cerebrovascular event), were evaluated. RESULTS: A total of 430 patients were implanted with an LVAD; mean age was 55 ± 13 years and 27% were female. The initial device strategy was bridge to transplant (BTT) in 50%, destination therapy (DT) in 29% and bridge to decision (BTD) in the remaining 21%. After a follow-up of 17 months, 97 (23%) patients had died during active LVAD support. Survival was 83% at 1 year, 76% at 2 years and 54% at 5 years. Patients implanted with an LVAD as a BTT had better outcomes compared with DT at all time points (1 year 86% vs 72%, 2 years 83% vs 59% and 5 years 58% vs 33%). Major adverse events were frequently observed, most often major infection, major bleeding and cerebrovascular events (0.84, 0.33 and 0.09 per patient-year at risk, respectively) and were similar across device strategies. Patients supported with HeartMate 3 had a lower incidence of major adverse events. CONCLUSIONS: Long-term survival on durable LVAD support in the Netherlands is over 50% after 5 years. Major adverse events, especially infection and bleeding, are still frequently observed, but decreasing with the contemporary use of HeartMate 3 LVAD.

16.
Heart ; 109(6): 478-484, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36270784

RESUMO

OBJECTIVE: Left atrial (LA) and left ventricular (LV) mechanics are impaired in patients with atrial functional mitral regurgitation (AFMR), but their prognostic value in this subset of patients remains unknown. The present study aimed to evaluate the association between LA and LV longitudinal strain and clinical outcomes in patients with AFMR. METHODS: A total of 197 patients (mean age 73±10 years, 44% men) with at least moderate AFMR were retrospectively identified. LV global longitudinal strain (GLS) and left atrial reservoir strain (LAS) were calculated by two-dimensional speckle tracking echocardiography. All-cause mortality was the primary endpoint of the study. The threshold value of LV GLS (≤16.3%) to identify impaired LV mechanics was defined based on the risk excess of the primary endpoint described with a spline curve analysis. RESULTS: Impaired LV GLS (≤16.3%) was found in 89 (45%) patients. During a median follow-up of 69 months, 45 (23%) subjects experienced the primary endpoint. Patients with impaired LV GLS (≤16.3%) had a significantly lower cumulative survival rate at 5 years, as compared with patients with LV GLS (>16.3%) (74% vs 93%, p<0.001). On multivariable Cox regression analysis, LV GLS expressed as continuous variable was independently associated with the occurrence of all-cause mortality (HR 0.856, 95% CI 0.763 to 0.960; p=0.008) after adjustment for age, LAS, pulmonary artery systolic pressure and severe tricuspid regurgitation. Conversely, LAS was not significantly associated with patients' outcome. CONCLUSIONS: In patients with significant AFMR, the impairment of LV GLS was independently associated with worse outcomes.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Prognóstico , Função Ventricular Esquerda , Estudos Retrospectivos , Deformação Longitudinal Global , Volume Sistólico
17.
JTCVS Open ; 16: 619-627, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204726

RESUMO

Objective: This study aimed to investigate the validity of simulation-based assessment of robotic-assisted cardiac surgery skills using a wet lab model, focusing on the use of a time-based score (TBS) and modified Global Evaluative Assessment of Robotic Skills (mGEARS) score. Methods: We tested 3 wet lab tasks (atrial closure, mitral annular stitches, and internal thoracic artery [ITA] dissection) with both experienced robotic cardiac surgeons and novices from multiple European centers. The tasks were assessed using 2 tools: TBS and mGEARS score. Reliability, internal consistency, and the ability to discriminate between different levels of competence were evaluated. Results: The results demonstrated a high internal consistency for all 3 tasks using mGEARS assessment tool. The mGEARS score and TBS could reliably discriminate between different levels of competence for the atrial closure and mitral stitches tasks but not for the ITA harvesting task. A generalizability study also revealed that it was feasible to assess competency of the atrial closure and mitral stitches tasks using mGEARS but not the ITA dissection task. Pass/fail scores were established for each task using both TBS and mGEARS assessment tools. Conclusions: The study provides sufficient evidence for using TBS and mGEARS scores in evaluating robotic-assisted cardiac surgery skills in wet lab settings for intracardiac tasks. Combining both assessment tools enhances the evaluation of proficiency in robotic cardiac surgery, paving the way for standardized, evidence-based preclinical training and credentialing. Clinical trial registry number: NCT05043064.

18.
Int J Cardiovasc Imaging ; 38(12): 2771-2779, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36445661

RESUMO

Pump thrombosis is a devastating complication after left ventricular assist device implantation. This study aims to elucidate the relation between left ventricular assist device implantation angle and risk of pump thrombosis. Between November 2010 and March 2020, 53 left ventricular assist device-patients underwent a computed tomography scan. Using a 3-dimensional multiplanar reformation the left ventricular axis was reconstructed to measure the implantation angle of the inflow cannula. All patients were retrospectively analyzed for the occurrence of pump thrombosis. In 10 (91%) patients with a pump thrombosis, the implantation angle was towards the lateral wall of the left ventricle. In only 20 patients (49%) of the patients without a pump thrombosis the inflow cannula pointed towards the lateral wall of the left ventricle. The mean angle in patients with a pump thrombosis was 10.1 ± 11.9 degrees towards the lateral wall of the left ventricle compared to 4.1 ± 19.9 degrees towards the septum in non-pump thrombosis patients (P = 0.005). There was a trend towards a significant difference in time to first pump thrombosis between patients with a lateral or septal deviated left ventricular assist device (hazard ratio of 0.15, P = 0.07). This study demonstrates that left ventricular assist device implantation angle is associated with pump thrombosis. Almost all patients in whom a pump thrombosis occurred during follow-up had a left ventricular assist device implanted with the inflow-cannula pointing towards the lateral wall of the left ventricle.


Assuntos
Coração Auxiliar , Trombose , Humanos , Coração Auxiliar/efeitos adversos , Cânula , Estudos Retrospectivos , Valor Preditivo dos Testes , Trombose/diagnóstico por imagem , Trombose/etiologia
19.
Surg Technol Int ; 412022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36265121

RESUMO

Growing interest in minimalizing surgical trauma during heart procedures stimulated the development of robotic mitral valve surgery in the late 1990s. Initially, the new technology was slowly adopted in clinical practice. However, following encouraging results by teams that adopted robotic heart surgery early on, a growing interest in implementation of robotic mitral valve surgery has emerged. Of importance are the technical developments and possibilities that accompany robotic surgery. Robotic arms feature unique characteristics, allowing unparalleled range of motion and allowing complex mitral valve repair techniques to be performed without limitations related to limited surgical incisions. High-quality three-dimensional vision effectively compensates for the lack of tactile feedback. Several technical solutions have been developed to facilitate mitral valve repair in minimal invasive setting, including chordal guiding systems, now available with various annuloplasty rings. On the other hand, precise vision and movements allows accurate determination of the length of implanted neochordae, facilitating precise determination of the length of implanted neochords even without the use of chordal-guiding systems. With robotic mitral valve surgery, leaflet resection techniques can be performed without limitations, ensuring that no compromises of the surgical strategy are made. Nevertheless, careful preoperative planning with appropriate work-up and imaging is of utmost importance to prevent complications. Moreover, the drawbacks of the initial learning curve and higher procedural costs are counterbalanced by less surgical trauma, lower utilization of blood products, and faster patient recovery. Robotic mitral valve surgery is still a young field and evolving technology that is bound to become an important tool in the toolbox of surgical mitral valve approaches.

20.
Front Cardiovasc Med ; 9: 969766, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312273

RESUMO

Left ventricular assist device (LVAD) implantation as destination therapy (DT) is a valuable treatment option in patients with end-stage heart failure ineligible for heart transplant. However, this therapy can be complicated by life-threatening pump thrombosis (PT). This case series reports our single-center experience with a structured systemic thrombolysis protocol in case of PT. Consecutive patients undergoing DT LVAD (HVAD, Medtronic, Framingham, MA) implantation between 2010 and April 2021 at our institution were reviewed and those with PT identified. Clinical, laboratory and LVAD specific data were collected and analyzed retrospectively. All patients with PT were treated with systemic thrombolysis according to a structured bedside protocol. Treatment was defined successful if a patient was alive at 30 days follow-up and free of recurrent PT, stroke or device exchange. Fourteen out of 94 patients experienced a PT after LVAD implantation (11%). Systemic thrombolysis was successful in 10 of 14 patients (71%) at 30 days. Two patients died within 30 days due to a hemothorax and multi-organ failure. In three patients treatment was complicated by a major bleeding; twice a hemothorax (one fatal) and one right calf bleeding. No intracerebral hemorrhage was observed. Three patients experienced a thrombotic complication within 30 days; all recurrent PT. Eleven of the 14 DT patients were discharged home after a limited hospital stay after thrombolysis (average of 11 days). In conclusion, systemic thrombolysis may be a reasonable option for life-threatening PT in this vulnerable DT group in whom device exchange is often impossible due to comorbidity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...